Harman Stove Company PC 45 Installation And Operating Manual page 10

Corn/pellet stove
Table of Contents

Advertisement

Fig. 14
Fig. 15
10
PC 45 Corn/Pellet Stove
Venting
#3 Installing into an existing
chimney ( US only )
This method provides excellent venting for nor-
mal operation. This method also provides natural
draft in the event of a power failure. If the chimney
condition is questionable you may want to install a
liner as in method #6.
#4 Installing into an existing
fireplace chimney ( US only )
This method provides excellent venting for nor-
mal operation. This method also provides natural
draft in the event of a power failure.
The damper area must be sealed with a steel
plate or fiberglass. A cap should be installed on the
chimney to keep out rain. If the chimney condition is
questionable you may want to install a liner all the
way to the top as in method #5.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents