Connecting to the mains
terminal
Warning: This appliance must be
earthed.
We recommend you use a new length
of 6mm
twin core and earthed cable to
2
ensure your safety.
Make connection as shown in Fig. 7 by
proceeding as follows:-
Preform wires to the appropriate shape
to suit fitting into the mains terminal
block.
Strip inner insulation on wires using
wirestrippers.
Twist the bared wires using pliers.
Cut bared wires 10mm away from the
end of the inner insulation.
uninsulated Earth wires are used
ensure they are suitably sheathed to
leave 10mm bare wire to fit into the
terminal.
Clamp bare wires into the relevant
terminal and check they are held by
tugging each one in turn.
Clamp the mains cable securely
ensuring 5mm of the outer insulation is
inside the terminal block and that the
wires are not taught but not so slack as
to cause any fouling. See Fig. 7.
Place fuse/miniature circuit breaker in
circuit and switch on at mains.