Flush Wall Installation
Combustible Surround Installation
Page 14
Figure 14
Figure 15
Attention: Cold climate installation recommendation: When
installing this unit against a non-insulated exterior wall, it is
recommended that the outer walls be insulated to conform
to applicable insulation codes.
vent Runs (Figures 16, 17, 18, 19 and 20)
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit.
vERTICAL, 90° ELBOW WITH HORIzONTAL TERMINATION
DVP36
49 ½" (126 mm)
TO BOTTOM
OF UNIT
Lp and Nat models
VENT CAP/
THIMBLE
THIMBLE
Figure 16
26930-5-1010