For Standing pilot Ignition Wiring
Appliance Requirements
DO NOT CONNECT 110-120 vAC TO THE GAS CONTROL
vALvE OR THE AppLIANCE WILL MALFUNCTION AND THE
vALvE WILL BE DESTROYED.
WIRING DIAGRAM
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
(OPTIONAL) WALL SWITCH
GREEN
BLACK
GREEN
30368-8-1113

STANDING pILOT WIRING

WARNING
STANDING PILOT WIRING DIAGRAM
(OPTIONAL) REMOTE CONTROL RECEIVER
RED
Optional Wall Switch
Position the wall switch in the desired position on a wall. Run a
maximum of 25 feet (7.8m) or less length of 18 A.W.G. minimum
wire and connect it to the fireplace valve pigtails.
DO NOT CONNECT THE 110-120 vAC TO THE WALL SWITCH
OR THE CONTROL vALvE WILL BE DESTROYED.
LABEL ALL WIRES pRIOR TO DISCONNECTION WHEN
SERvICING CONTROL. WIRING ERRORS CAN CAUSE IM-
pROpER AND DANGEROUS OpERATION. vERIFY pROpER
OpERATION AFTER SERvICING.
REMOTE CONTROL RECEIVER
H
N
REMOTE/OFF/ON SWITCH
REMOTE/OFF/ON SWITCH
REMOTE
OFF
ON
THERMOPILE
GAS VALVE
THERMOCOUPLE
WARNING
WARNING
GAS VALVE
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150°C
WIRE OR ITS EQUIVALENT.