8.
Turn the Power Supply Controller to the
desired current (15 to 40 amps).
9.
Adjust air pressure by turning the
Pressure Regulator Knob on top of
the unit (see photo on page 9). Read
pressure on Pressure Gauge.
10.
When everything is in place for cutting,
press the Power Switch UP to the ON
position. The green Power On Light
will illuminate, but the Torch is not yet
energized.
11.
Orient yourself to one side of the area
to be cut, and move the Welding Helmet
Face Shield (not included, see page 5
item 7) over your eyes.
12.
Be CAreFul! PIlOt PlAsmA ArC
CAn severelY Injure. Once the
trigger is squeezed, the arc will ignite.
this unit provides a pilot arc, so the
torch does not need to contact the
workpiece before the cutting arc
ignites.
3A
4A
5A
6A
7A
13. (Refer to parts diagram above for Torch
Handle components.) direct torch away
from people and flammables while you
squeeze (and hold) the Torch Handle
Trigger (2A) to energize the Torch
Electrode (4A). The air output is delayed
SKU 95136
1A
2A
Part description
1A
Handle
2A
Trigger
3A
Body
4A
Electrode
5A
Insulating Diffuser
6A
Nozzle
7A
Nozzle Holder
For technical questions, please call 1-800-444-3353.
a few seconds to enable a proper arc to
begin.
Caution: The Torch handle is now energized.
Be careful not to touch anything else with
the Torch except the workpiece to be cut.
Warning: never look at the ignited arc
without AnsI-approved, arc shaded,
eye protection in a full face shield.
Permanent eye damage or blindness
can occur. skin burns can occur.
never breathe arc fumes.
14.
Bring the Electrode (4A) of the Torch
close to the starting point of the cut. The
Working Indicator Light will come on.
15.
Slowly move the Torch at a slight angle
along the cutting line with the Torch tip
trailing.
The air causes the molten metal to fall
away from the workpiece being cut. If
proper cutting is not achieved, adjust
the Power Supply Controller to a higher
level, and/ or increase air flow. To
increase air flow, press the Power Switch
to the Off (O) position, then adjust the air
pressure at the Air Pressure Regulator.
The air will continue to come out of the
Torch Handle for a few seconds once the
trigger is released.
note: If too much current is drawn from the
Plasma Cutter (i.e., short circuit), the
Thermal Switch, an overload protector,
will activate and the red Thermal
Overload Indicator Light will light. The
Plasma Cutter will turn off until it cools
down. To reset you must turn the power
OFF then back ON. Press the Trigger to
begin cutting again.
16.
When finished cutting:
a.
Release the Torch handle trigger and lift
the Torch handle from the workpiece,
b.
Press the Power Switch to the Off (O)
position,
Page 11