Be CertAIn to shut off the Plasma Cutter, and disconnect it from power and air before
adjusting, cleaning, or repairing the unit. A technician should discharge all capacitors before
performing any internal procedures.
PrOBlems
reduCed
take into account the thickness and type
of metal to be cut before you start. thin-
ner materials will typically require lower
amp settings.
tOrCh In gOOd
COndItIOn
Air supply pressure may be inadequate:
a. verify that the compressor is delivering
at least 3.5 CFm @ 80 PsI to the tool.
b. the regulator on the unit must be set
to at least 60 PsI.
If the steps above do not solve the problem or if the repairs involved are too
rev 07h
SKU 95136
trOuBleshOOtIng
FAst nOzzle WeAr
exCessIve slAg FOrmAtIOn
these two problems have similar causes
and will often appear simultaneously.
the same diagnostic procedures and
remedies apply to both.
the Amperage setting may be too high;
try cutting at a lowest setting possible for
the metal being cut.
complex, contact a qualified technician.
For technical questions, please call 1-800-444-3353.
(COntInued)
ImPOrtAnt!
Or
disconnect the torch Cables.
disassemble the torch assembly and
inspect all internal components, as ex-
plained on page 11.
replace any damaged or missing compo-
nents and reassemble carefully, following
the directions on pages 9-11.
PrOBlems PersIst At
lOWest PrACtICAl settIng
dAmAged
COmPOnents FOund