Gas Connection - Smeg Oven Instructions For The User

Hide thumbs Also See for Oven:
Table of Contents

Advertisement

Instructions for the installer
2.3
This appliance is suitable for installation with Natural Gas
or ULPG (propane). Refer to page 12 for the relevant
burner pressure and appropriate injector sizes. When the
appliance is to be connected to Natural Gas then the
pressure regulator supplied must be fitted to the gas inlet.
A test point (for checking the gas pressure) is supplied
either with the regulator or as a separate fitting in the case
of ULPG (propane) appliances.
Connection of the appliance to the gas supply must be in
accordance with the requirements of AS5601. A ½" BSP
connector at the inlet is recommended and the gas supply
line to the appliance must be of adequate length to allow
sufficient
disconnection and be:
1.
2.
The cooker must be installed with provision to allow the gas to be turned off
and disconnected for servicing and removal of the appliance as required
from the gas supply.
Before the cooker is operated make certain all relevant parts are placed in
the correct position.
When the installation is completed the installation connections of cooker will
require to be leak tested, the burner operating pressure and flame checked
and adjusted.
Warranty service calls do not cover these adjustments!
To check the operating pressure of the appliance it is recommended at least
2 large size burners are used. Ensure appliance is secured to wall when
installation is completed.
N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of
the appliance. An approved manual shut-off valve must be installed. The
N.G. regulator must be checked and adjusted to 1.0kPa after installation.
ULPG: Can be connected to the inlet fitting
directly. The pressure must be checked to
ensure it is operating at 2.75kPa. A separate
test point fitting must be installed between the
piping & the appliance for the pressure to be
checked to ensure it is operating at 2.75kPa.
8

Gas connection

withdrawal
of
annealed copper pipe or;
flexible hose according to AS/NZ1869 & be at
least Class "B", 10 mm diameter.
appliance
for
service
or