Troubleshooting Guide - NuTone VX1000C Installation Instructions Manual

Built-in central cleaning system
Hide thumbs Also See for VX1000C:
Table of Contents

Advertisement

TROUBLESHOOTING GUIDE

Trouble
1. Loss or decrease of vacuum
occurs.
2. Power Unit does not start,
or shuts off during normal
operation
with
no
showing Red or illuminated.
3. Power Unit fails to stop when
the hose is removed.
4. Power Unit shuts off during
normal operation, lights on
Unit, Wall Valve and Hose
are all Red.
5. For VX550 & VX1000 Series.
All lights on control panel
flash when unit is first
plugged in.
Read Before Calling Service Center
Possible Cause
1a. Disposable filter bag or debris bucket are completely full.
1b. Obstruction in the hose. A blockage in the hose can be determined by
inserting the hose into any Wall Inlet and, while Power Unit is running, check
each additional inlet for normal suction by holding the palm of your hand over
the open inlet. If normal suction is felt at all other inlets, insert the hose into a
second inlet. If the blockage still exists it is located in the hose. However,
if the blockage does not occur when the hose is changed, the blockage is
probably located in the tubing system leading to the original inlet.
1c. Obstruction in the tubing system inside the walls.
1d. Wall Inlet cover not properly sealed.
1e. Exhaust tubing or vent clogged.
2a. Defective inlet. Check other Wall Inlets.
LED
2b. Thermoprotector has been activated.
2c. Blown fuse or tripped circuit breaker.
2d. Defective hose.
2e. Note: This would apply only to the VX550 & VX1000:
Microprocessor Lockup.
2f. Low Line Voltage
2g. Bag full sensing has been activated.
3a. An electrical short has occurred somewhere in the system.
4a. Debris bucket and/or direct door not fully closed or attached.
5a. Two or more hoses may be plugged into system.
36