CI390 & CI395 ELECTRAVA LV E
ELECTRIFIED INLET
INSTALLATION
(CI395RK Rough-In)
(Not available in Canada)
1. See Figure 27. Fasten the mounting plate to a stud
within three studs (48") of an electrical outlet box.
Measure and mark the wire 10" from the plug (A).
Feed the wire through the top hole in the mounting
plate (just above the circular opening). Snap the
molded plug into the mounting plate as pictured (B).
This will keep it secure and out of harm's way during
drywalling and finishing. Line up the wire at the pre-
viously measured 10" mark with the strain of relief
channel on the back of the mounting plate. Secure it
in place with the supplied wire tie (C).
2. Run the inlet wire to the adjacent electric box. If you
must run wire through a stud, drill directly through
the center of the stud (D).
3. See Figure 28. Place the exposed ends of the two
wires into the electrical box through a strain relief
channel (E). Tighten the strain relief channel (do not
overtighten) on the white sheathing leaving 1⁄2" of
this sheathing exposed inside of the outlet box.
Fold the 6" of black and white wire into the outlet box.
Leave the wires to be connected by the electrician when
plug receptacles are being installed. (Attention: Power
tools such as routers are not recommended for use with
the inlet installation, as removal of drywall with these
devices may cause damage to the mounting plate and/or
inlet plug).
4. Once drywall and finishing processes have been
completed, remove molded plug from mounting plate
(with the aid of a slot screwdriver) and snap it into
the wing slot at the back of the inlet (F). (Please
note: molded plug fits one way only, with the narrow
opening at the top). Insert inlet into the mounting
plate and secure inlet to mounting plate with screws
provided.
NOTE:
All electrical devices such as the electrified inlet
should be reported to the construction electrician for listing
on the inspection report for building inspection purposes.
NOTE:
Plumb inlet to tubing using NuTone Model CF382S
90° Ell fitting.
NOTE:
All location and installation direct connect
electrified wall valves must conform with all local and
municipal building codes.