Checking before use

Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the
table for efficient use.
Mode
Indoor temperature
Cooling
Heating
Dry
If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of
specified capacity according to the using conditions.
Maintaining your air conditioner
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type
Against cold air
De-ice cycle
Protect compressor
• If the heat pump is operating in Heat mode, De-ice cycle is actuated to help remove frost from an outdoor unit that
may have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the de-ice cycle is completed.
• A Samsung-branded air conditioning unit installed in an area which is not easily accessible (including without
limitation roofs or positions above 2.4 metres for the outdoor unit) may require additional costs for labour and
access equipment as may be mandated by occupational health and safety requirements. Such costs are to be
borne by you should service or maintenance (including service or maintenance covered by your warranty or by
a consumer guarantee) be required.
10
Australia_AQV24&30T@_IB&IM_EN_03562A(1).indd 10
Outdoor temperature
16˚C~32˚C
-10˚C~46˚C
27˚C or less
-15˚C~24˚C
18˚C~32˚C
-10˚C~46˚C
The internal fan will be off to against cold air when the heat pump is heating.
The internal fan will be off to defrost ice when the heat pump is heating.
The air conditioner does not start operating immediately to help protect the compressor
of the outdoor unit after it has been started.
Indoor humidity
Relative humidity 80% or less
-
-