Samsung AQV36W Series Installation Manual
Samsung AQV36W Series Installation Manual

Samsung AQV36W Series Installation Manual

Split-type air conditioner (cooling and heating)
Hide thumbs Also See for AQV36W Series:

Advertisement

Quick Links

INSTALLATION
MANUAL
AQV36W
Split - type Air Conditioner
(Cooling and Heating)
E
S F
DB98-29387A(1)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AQV36W Series

  • Page 1 INSTALLATION MANUAL AQV36W Split - type Air Conditioner (Cooling and Heating) DB98-29387A(1)
  • Page 3: Safety Precautions

    Safety Precautions The following safety precautions must be taken when using your air conditioner. • If you don’t follow the safety precautions, you may get the risk of an WARNING electric shock, injury or death. • The manufacturer or qualified service personnel must install this air conditioner. •...
  • Page 4: Table Of Contents

    Contents  REPARING THE INSTALLATION Deciding the Installation Place ....... . . 4 ...
  • Page 5: Preparing The Installation

    REPARING THE NSTALLATION Deciding the Installation Place You should observe the following restrictions when you decide the installation place. General Do NOT install the air conditioner under the following conditions;  Combustible gases  Saline air  Machine oil  Sulfide gas ...
  • Page 6 REPARING THE NSTALLATION Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner. 11.8inch(300mm) or more 4.9inch(125mm) 4.9inch(125mm) or more or more Wrap the refrigerant pipes and the You can select the direction of drain hose with the absorbent pad draining.
  • Page 7: Accessories

    REPARING THE NSTALLATION Accessories The following accessories are supplied with the air conditioner. The number of each accessory is indicated in parentheses.  Accessories in the Indoor Unit Case Installation Plate (1) Remote Control (1) Batteries for User’s Manual (1) Installation Manual (1) Service Manual (1) Remote Control (2)
  • Page 8: Fixing The Installation Plate

    0.8inch(20mm). 19.5F 64.5E Determine the positions of the wooden uprights to be attached to the window frame. AQV36W  Inch Attach the wooden uprights to the window frame giving attention to the 6.14 weight of the indoor unit.
  • Page 9: Connecting The Assembly Cable

    NSTALLING THE IR CONDTIONER Connecting the Assembly Cable The outdoor unit is powered from the indoor unit through the assembly cable. If the outdoor unit is more than 24.6ft(7.5m) away from the indoor unit, you must extend the cable. The maximum length of the cable is 98.4ft(30m). Extend the assembly cable if necessary.
  • Page 10: Installing And Connecting The Drain Hose Of The Indoor Unit

    NSTALLING THE IR CONDTIONER Installing and Connecting the Drain Hose of the Indoor Unit When installing the drain hose for the indoor unit, you should check if condensate draining is adequate. When you pass the drain hose through the 65mm hole drilled in the wall, check the following. 2inch (50mm) Ditch...
  • Page 11: Installing And Connecting The Assembly Pipe Of The Indoor Unit

    NSTALLING THE IR CONDTIONER Installing and Connecting the Assembly Pipe of the Indoor Unit There are 2 refrigerant pipes of different diameters: The smaller one is for the liquid refrigerant  The larger one is for the gas refrigerant  A short pipe is already fitted to the air conditioner.
  • Page 12: Cutting Or Extending The Pipe

    NSTALLING THE IR CONDTIONER Cutting or Extending the Pipe A 5-meter pipe is supplied with the air conditioner. (Optional) The length of the pipe can be: Extended up to 98.4ft(30m)  Shortened as required   If you need a pipe longer than 24.6ft(7.5m): You must extend the assembly cable.
  • Page 13: Completing The Installation

    OMPLETING THE NSTALLATION Purging the Connected Pipes The outdoor unit is loaded with sufficient R22 refrigerant for a 24.6ft(7.5m) pipe You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling and heating capacity and malfunction.
  • Page 14: Performing The Gas Leak Tests

    OMPLETING THE NSTALLATION Performing the Gas Leak Tests You must check if there is a gas leak before completing all the installation process. (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate) To check for gas leaks on the...
  • Page 15: Fixing The Outdoor Unit In Place

    OMPLETING THE NSTALLATION Fixing the Outdoor Unit in Place You should install the outdoor unit on a stable base to avoid the generation of noise and vibration, especially when installing the outdoor unit close to your neighbor. If you install the outdoor unit in a place exposed to strong winds or at a height, you must fix it to the appropriate support (wall or ground).
  • Page 16: Providing Information For User

    OMPLETING THE NSTALLATION Providing Information for User After finishing the installation of the air conditioner, you should explain the following to the user. Refer to appropriate pages in the User’s Manual. How to start and stop the air conditioner How to select the modes and functions How to adjust the temperature and fan speed How to adjust the airflow direction How to set the timers...
  • Page 17 Printed in Korea...

Table of Contents