Connection with the Camera Site

Connect the Camera Site equipment to the Camera
Input Connectors (CAMERA IN 1-8) on the rear of the
Data Converter.
Connect the Camera Site equipment to the RS485
Terminal on the rear of the Data Converter, when speci-
fied equipment is connected.
CAMERA
CAMERA
OUT
Cautions:
• The multiplexed camera site alarm, including motion detector, is not effective with the AD equipment.
To prevent malfunction in the system, set the camera site alarm to the OFF position.
• If the RS485 cameras are connected to the RS485 Terminal, set the parameters of the cameras for RS485 site com-
munication as shown below.
Unit Number:
Data Bit:
Parity Check:
Stop Bit:
Baud Rate:
AUX
8
7
6
5
IN
8
7
6
5
To AD equipment
1
8
None
1
As set by SW3
(See page 6)
Note: If you use cables assembled from locally pro-
cured materials, it is important that only high quality,
data grade cable, suitable for RS485 "2-wire twisted
pair shielded cable" is used.
Low grade cable will result in unstable operation of
the system.
3
4
2
R
T
G
B
A
B
A
G
3
4
Data Converter
WJ-DC108AD
-11-
To AD equipment
1
R
T
B
A
B
A

Advertisement