If you prefer, dryer may be converted to exhaust through
the bottom. You must contact your local dealer to have dryer
converted.
A
B
A. Standard
rear offset exhaust installation
B. Bottom exhaust installation
Alternate
installations
for close
clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance
installations are shown.
Refer to the manufacturer's
instructions.
A
B
A. Over-the-top
installation
(also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase. Contact your local dealer.
[]
[]
Over-the-Top
Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)
mismatch
Special
provisions
for mobile
homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
Mobile Home Exhaust installation
Determine
vent path:
[] Select route that will provide straightest
and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90 ° turns as possible.
Determine
vent
length
and elbows
needed
for best
drying
performance:
[] Use following Vent System Chart to determine type of vent
material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
[] Shorten life of dryer.
[] Reduce performance,
resulting in longer drying times
and increased energy usage.
The Vent System Charts provide venting requirements that
will help achieve best drying performance.
Whirlpool
Vent System
Chart
Number
of
Type
Box/Iouvered
Angled
90 ° elbows
of vent
hoods
hoods
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m)
48 ft. (14.6 m)
2
Rigid metal
44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
14