Maytag MED4200BW0 Installation Instructions Manual page 11

Electric dryer
Table of Contents

Advertisement

Remove
center
screw
Connect ground wire (green or bare) (F) of direct wire cable
under green external ground conductor screw (A). Tighten
screw.
Connect
remaining
wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Finally, reinsert tab
of terminal block cover into slot of dryer rear panel. Secure
cover with hold-down screw. Now, go to "Venting Requirements".
3=Wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground
conductor
to neutral wire.
f
1.
Prepare
your 3=wire cable
for direct
connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 31/2" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
Remove center terminal block screw (B).
Connect
neutral wire
B
C
Place hooked end of neutral wire (white
or center) (C) of direct wire cable under
center terminal block screw (B), hook
facing right. Squeeze hooked end together.
Tighten screw.
4,
Connect
remaining
wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze hooked
ends together and tighten screws. Finally, reinsert tab of terminal
block cover into slot of dryer rear panel. Secure cover with
hold-down screw. Now, go to "Venting Requirements."
11