Connecting The Range - Magic Chef CGS1740ADH Installation Manual

Gas 30-inch free-standing and slide-in
Hide thumbs Also See for CGS1740ADH:
Table of Contents

Advertisement

CONNECTING
THE RANGE
ELECTRIC
SUPPLY
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code,
ANSI/NFPA 70.
In Canada the range must be installed in accordance with
the current CSA Standard C22.1 - Canadian Electrical
Code Part 1.
ELECTRICAL
SUPPLY
CONNECTION:
The range requires 120 volts, 60 cycle alternating current
from an outlet. See serial plate for rating.
User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCl) outlet or breaker is in use.
kWARNING
Electrical
Grounding
Instructions
This appliance
is equipped
with
a (three-prong)
grounding
plug for your
protection
against
shock
hazard
and
should
be plugged
directly
into
a
properly
grounded
receptacle.
Do not cut or remove
the grounding
prong from this plug.
kWARNING
DISCONNECT
ELECTRICAL
SUPPLY
BEFORE
SERVICING
THE APPLIANCE.
GAS SUPPLY
Installation of this range must conform with local codes or,
in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1-1atest edition.
In Canada the range must be installed in accordance with
the current CGA Standard CAN/CGA-B149 - Installation
Codes for Gas Burning Appliances and Equipment and/or
local codes.
In The Commonwealth
Of Massachusetts
This product must be installed by a licensed plumber or
gas fitter when _nstalled within the Commonwealth
of
Massachusetts.
A "T" handle type manual gas valve must be installed in
:he gas supply line to this appliance.
A flexible gas connector, when used must not exceed a
length of three (3) feet/36
inches.
GAS SUPPLY
CONNECTION:
(See figure 4)
A QUALIFIED SERVICEMAN OR GAS APPLIANCE
INSTALLER MUST MAKE THE GAS SUPPLY
CONNECTION.
Leak testing of the appliance shall be
conducted by the installer according to the
instructions given in section h.
NATURAL GAS SUPPLY LINE MUST HAVE A NATURAL
GAS SERVICE REGULATOR. INLET PRESSURE TO
THIS APPLIANCE SHOULD BE REDUCED TO A
MAXIMUM OF 14 INCHES WATER COLUMN (0.5
POUNDS PER SQUARE INCH (P.S.I.) LIQUEFIED
PETROLEUM (LP.)/PROPANE
GAS SUPPLY LINE
MUST HAVE ALP.
GAS PRESSURE REGULATOR.
INLET PRESSURE TO THIS APPLIANCE SHOULD BE
REDUCED TO A MAXIMUM OF 14 INCHES WATER
COLUMN (0.5 P.S.I.). INLET PRESSURES IN EXCESS
OF 0.5 P.S.I. CAN DAMAGE THE APPLIANCE
PRESSURE REGULATOR AND OTHER GAS
COMPONENTS
IN THIS APPLIANCE AND CAN
RESULT IN A GAS LEAK.
a.
A GAS CUTOFF VALVE SHOULD BE PUT IN AN
ACCESSIBLE
LOCATION IN THE SUPPLY LINE
AHEAD OF THE RANGE, FOR TURNING ON AND
TURNING OFF GAS SUPPLY. If range is to be
connected to house piping with flexible or semi-rigid
metal connectors for gas appliances, CONNECTOR
NUTS MUST NOT BE CONNECTED DIRECTLY TO
PIPE THREADS. THE CONNECTORS
MUST BE
INSTALLED WITH ADAPTORS PROVIDED WITH
THE CONNECTOR.
b.
The house piping and/or range connector used to
connect the range to the main gas supply must be
clean, free of metal shavings, rust, dirt and liquids (oil
or water). Dirt, etc. in the supply lines can work its
way into the range manifold and in turn cause failure
of the gas valves or controls and clog burners and/or
pilot orifices.
CAUTION: DO NOT LIFT OR MOVE RANGE BY
DOOR HANDLES, OR BACKGUARD.
c.
Turn off all pilots and main gas valve of other gas
appliances.
d.
Turn off main gas valve at meter.
e.
Before connecting range, apply pipe thread
compound approved for LPG to all threads.
Connect range to gas supply at appliance pressure
regulator using adaptors supplied with flexible
connector. Rigid pipe may also be used. See rating
plate for type of gas range has been manufactured
for.
g.
Turn on main gas valve at meter, and relight pilots at
other gas appliances.
-5-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cgs1740adlMgs5770adcCgs1740adt

Table of Contents