Chauvet Intimidator Spot LED 250 User Manual page 24

50-watt led moving head spot
Hide thumbs Also See for Intimidator Spot LED 250:
Table of Contents

Advertisement

(DMX Connectivity cont.)
Number of Fixtures
DMX Data Cabling
Making Your Own
DMX Cable
DMX Cable Characteristics
DMX Cable Connectors
Page 24 of 26
When using a DMX controller, the combined number of channels required by
all the fixtures on the DMX daisy chain determines the number of fixtures the
DMX controller has to support. Conversely, the number of onboard sliders,
page buttons, and fixture buttons limits the number of discrete DMX channels
a DMX controller can support.
To comply with the EIA-485 standard, which is the base for the USITT
DMX512-A protocol, do not connect more than 32 fixtures without using
an optically-isolated DMX splitter. Doing otherwise may result in
deterioration of the digital DMX signal.
You must use DMX compliant data cables to link two or more DMX compatible
fixtures. You may purchase CHAUVET® certified DMX cables directly from a
dealer/distributor or construct your own cable.
USITT recommends limiting the total length of the DMX cable (from the
first fixture/controller to the last fixture) to 300~455 m (985~1,500 ft).
If you choose to create your own DMX cable, make sure to use data-grade
cables that can carry a high frequency signal and are less prone to
electromagnetic interference. Use a Belden® 9841 or equivalent cable, which
meets the specifications for EIA RS-485 applications. For certain applications,
Cat5, Cat5e, or Cat6 may be appropriate.
Do not use standard microphone cables for DMX applications because
they cannot transmit DMX data reliably over long distances.
The DMX data cable must have the following characteristics:
Type:
Maximum capacitance between conductors:
Maximum capacitance between conductor and shield:
Maximum resistance:
Nominal impedance:
Each DMX cable must have a male (3-pin or 5-pin XLR connector) on one end
and a female (3-pin or 5-pin XLR connector) on the other end.
DMX Connector Configuration
To DMX Input
(Female)
1
3
2
To avoid signal transmission
problems and interference,
connect a DMX signal terminator
to the last fixture in the
DMX daisy chain, as shown.
shielded, 2-conductor twisted pair
To DMX Output
(Male)
Common
DMX +
DMX -
1
3
2
Intimidator™ Spot LED 250 User Manual (Rev. 03)
30 pF/ft
55 pF/ft
20 ohms/1000 ft
100~140 ohms
1
3
2
120 ohm, ¼ W
resistor between
pin 2 (DMX -) and
pin 3 (DMX +) on
the output of the
last fixture.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intimidator beam led 350

Table of Contents