REQUIREMENTS
Stacked Washer/Gas Dryer Gas Supply Requirements
Explosion Hazard
Connect this dryer to a regulated gas supply. Supply
pressure must be in accordance
with the Technical
Specifications.
Install a shut=off valve.
Securely tighten
aft gas connections.
if connected to LP, have a qualified person make sure
gas pressure is correct.
Failure to do so can result in death, explosion, or fire.
I M PORTANT:
Observe
all governing
codes and ordinances.
In Australia and New Zealand,
refer to AS/NZS
5601.1
- Gas
Installations.
Gas
Supply
Before
installation,
check that the local gas distribution
conditions,
nature of gas and pressure,
and the adjustment
of the appliance
are compatible.
Burner
information
will be found on the model/
serial rating plate in the door recess
of the dryer. If this information
does not agree with the type of gas available,
see your dealer.
Natural Gas:
This dryer is factory adjusted for use with NATURAL GAS (G20),
and no further adjustment should be required at installation.
L.P. Gas:
This dryer is also certified
for use with L.R (propane
or butane)
gases with appropriate
conversion.
No attempt
shall be made to
convert the appliance
from the gas specified
on the model/serial
rating plate for use with a different
gas without
consulting
the
serving
gas supplier.
Conversion
must be done by a competent
service technician.
Gas
conversion
kit (European
Country),
part number W10233219,
is available
for purchase
from your dealer. Gas conversion
kit
(Australia),
part number W10315369,
is available
for purchase
from your dealer. Full instructions
are supplied
with the kit.
Natural
gas (France/Belgium):
This dryer is also certified
for France/Belgium
for use with G20/
G25 gases (20 mbar/25
mbar) with appropriate
conversion.
No attempt
should
be made to convert this appliance
from the
gas specified
on the gas rating label for use with a different
gas
without
consulting
the serving
gas supplier.
Gas conversion
must
be done by a qualified
gas service technician.
Conversion
kit, part
number
(W10181947)
is available
for purchase
from your dealer.
Full instructions
are supplied
with the kit.
Supply
line requirements:
Provide a rigid gas supply
line to the washer/dryer
location.
It
should
be minimum
12.5 mm (1/2")
ID. When acceptable
to the
gas supplier
and local codes,
10 mm (3/8")
ID rigid supply
line
may be used for lengths
under 6.1 m (20'). Pipe-joint
compounds
resistant
to the action of L.R gas must be used.
NOTE: For installation in Australia
and New Zealand,
refer to
AS/NZS
5601
for pipe sizing details. All piping is to be in
accordance
with AS/NZS
5601.1
- Gas Installations.
Gas connection
to the dryer itself should
be made by means
of a flexible gas hose suitable
for the appliance
and gas category
in accordance
with national
installation
regulations.
If in doubt,
contact
the gas supplier.
It should
be minimum
10 mm (3/8")
ID.
A means of restraint
should
be used between
the washer/dryer
and the wall to avoid straining
of the rigid gas supply when the
washer/dryer
is moved. An appropriate
length of chain and a wall
hook is recommended.
The dryer gas inlet connection
is a 3/8" NPT thread. An adapter
is
supplied
for conversion
to standard
ISO.228-1
thread (3/8"
BSP).
Check for leaks by using an approved
noncorrosive
leak-detection
solution.
Bubbles
will show a leak. Correct
any leak found. A
pressure
measurement
tapping
is provided
on the gas valve within
the dryer, accessible
after removal of the lower front panel.
The dryer must be disconnected
from the gas supply
piping
system
during any pressure
testing
of that system.