calIbRaTIng The scanneR

1 .
Place the Scanner on the White Balance Calibration Sheet and press
the POWER/SCAN button for two seconds to turn the unit on .
2 . Press and hold the C/BW button . While holding the C/BW button,
press the POWER/SCAN button once to enter into auto-calibration
mode . The microSD CARD INDICATOR will flash and stop when
the internal memory clearing process is complete .
3 . The green and red LED light will then turn on . Do not move the
Scanner until the red LED light turns off . The green LED will remain lit .
4 . Start rolling the Scanner over the White Balance Calibration Sheet slowly
and evenly until the green light turns off (you may have to roll the Scanner
backwards if necessary) .
5 . When the green LED light turns off, the calibration is complete .
Press and hold the POWER/SCAN button to turn the Scanner off .

seTTIng The ResolUTIon

1 . Turn the Scanner on by pressing the POWER/SCAN button for two seconds .
2 . By pressing the DPI RESOLUTION button on the scanner, you may choose
between high resolution (600 dpi) and low resolution (300 dpi) .
3 . The high or low resolution mode will be displayed on the LCD screen
to reflect your choice .