Download Print this page

Payne PYIP180040 Installation, Start-Up And Service Instructions Manual page 5

Py1p single packaged gas heating/ electrical cooling units

Advertisement

GIG"
(23, B)
+45
1/2"
CON0 C0IL
(115B,71
/
43
11/16"
1110B.8)
(281,4)
(433+a1
AIR
OPENING
14 ?/16"
(355.9)
1,
t
L2
1116"
(52,6)
10
BilE"
(268.91
5/B"
:39B,91
BLOWER
ACCESS
BURNER
ANO
CONTROL
BOX
PANEL
RIGHT
SIDE
VIEW
ACCESS
PANEL
ACCESB PANEL
13/15"
3/4"
NPT
{15.0)
DRAIN
OUTLET
J
3115"
(55,B1
FRONT
VIEW
FLUE
HO00
1B 1/15
(458.8)
L__
B 518"
(142.9)
r-
1B/16:
_lO
"_
(29.5)
(253.5)
I
114"
(31,7G3
ALTERNATE
POWER ENTRY
EVAP COIL
ACCEBB
\,
\
\
/16"
REQ'D CLEARANCES
FOR SERVICING.
in. (ram)
Duct panel .............................
0
Unit top ...........................
36 (914)
Side opposite
ducts
.....................
36 (914)
Compressor
access
.....................
36 (914)
(Except for NEC requirements)
REQ'D CLEARANCES
TO COMBUSTIBLE
MAT'L. in (ram)
Maximum extension
of overhangs
...............
48 (1219)
Unit top ...........................
14 (356)
Duct side of unit
........................
2 (51)
Side opposite
ducts
.....................
14 (356)
Bottom of unit
...........................
0
Flue panel
.........................
36 (914)
NEC REQ'D CLEARANCES.
in. (ram)
Between
units, controt box side ................
42 (1867)
Unit and ungrounded
surfaces,
control box side
.........
36 (914)
Unit and block or concrete walls and other grounded
surfaces,
control box side
..................
42 (1067)
2
1116"
(G2.3)
_
?%Nf&2 NT ¢7
1 13116'
29
7/8"
32
1/4"
(287.3)
,8,B.B) I
4_I
t18"
(2B.G)
OIA+
POWER
ENTRY
to
,
/
1 B/B"
(41=31
OIA.
GAS
ENTRY
I/2"
- 14 NPT
FLUE
PANEL
GAS CONNECTION
UNIT
ELECTRICAL
CHARACTERISTICS
PYIP048080
208/230-1-60,208/230-3-60,460-3-60
PY1P048100/120/140
208/230-1-60,208/230-3-60,460-3-60
PYIP060OBO
208/230-1-60,208/230-3-60,460-3-60
PYIP060100/120/140
208/230-1-60,208/230-3-60,460-3-60
UNIT WEIGHT
Ib
kg
438
199
450
205
477
217
489
222
A
113/51
116/53
123/56
126/57
CORNER WEIGHT
(Ib/kg)
B
C
89/40
164/75
92/42
165/75
99/45
173/79
182/46
173/79
D
72/33
77/35
82/37
88/40
UNIT
PY1P048080
PY1P048100/120/140
PY1P060080
PY1P060100/120/140
CENTER OF GRAVITY
(in./mm)
X
Y
Z
28.54/7249
2000/508
1766/4486
28.22/7168
2005/5093
1766/4486
28.18/7156
2019/5128
1766/4486
27.79/7059
2023/5138
1766/4486
LEGEND
CG
--
Center of Gravity
MAT'L
--
Material
COND
--
Condenser
NEE
--
National Electrical Code
LV
--
Low Voltage
REQ'D
--
Required
NOTES:
1. Clearances must be mahTtained to prevent redrculation of air from outdoor-
fan discharge
2. Adequate
clearance around air openings into combustion
chamber must
be provided.
Fig. 5 -- PYIP048,060
With Optional Base Rail, Unit Dimensions
--5--

Advertisement

loading