10. Adjust the leveling legs to the correct height. Leveling legs
can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of 3/16" (5 mm) is needed to engage the anti-tip
bracket.
11. Move the range into final position making sure the rear
leveling leg slides into the anti-tip bracket.
12. If installing the range in a mobile home, you must secure the
range to the floor. Any method of securing the range is
adequate as long as it conforms to the standards in the
"Location Requirements" section.
13. Continue installing your range using the following installation
instructions.
1. Make sure the anti-tip bracket is installed:
[] Look for the anti-tip bracket securely attached to the floor.
[] Slide the range back so the rear range foot is under the anti-tip
bracket.
A.Anti-tip bracket
B. Rangefoot
2. If installing the range in a mobile home, you must secure the
range to the floor. Any method of securing the range is
adequate as long as it conforms to the standards in the
"Location Requirements" section.
3. Continue installing your range using the following
installation instructions.
1. Place rack in oven.
2. Place level on rack and check levelness of the range, first side
to side; then front to back.
3. If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket. Use %" drive ratchet and
slip-joint pliers to adjust leveling legs up or down until range is
level.
4. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
Typical rigid pipe connection
A combination
of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.
1. Apply pipe joint compound
made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
G
....................
A. Pressure regulator
D. Union
connection fitting
E. Nipple
B. 90° elbow
E Manual shutoff valve
C. Black iron pipe
G. V2"to 3/4"gas pipe
Typical flexible connection
1. Apply pipe joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and F in following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a combination wrench to attach the flexible connector to
the adapters. Check that connector is not kinked.
A
g
E
............... _
.................
F
H
A. Pressure regulator
connection fitting
B. Use pipe joint compound
C. Adapter
D. Flexible connector
E. Adapter
E Use pipe joint compound
G. Manual shutoff valve
H. V2"to 3/4'_ g as pipe

Advertisement