30"(76.2cm) freestanding gas range with standard clean oven
Hide thumbs Also See for WFG114SVT0:

Advertisement

Flexible m etal a ppliance connector:
[] Iflocal c odes p ermit, anew CSA design-certified,
4-5ft
(122-152.4
cm)long, 1 /2" (1.3 cm) o r3/4" (1.9 cm) I .D., f lexible
metal appliance connector may beused forconnecting range
tothegassupply l ine.
[] A1/2" (1.3 cm)male pipe thread i sneeded forconnection to
thefemale p ipe threads oftheinlet t otheappliance gas
pressure regulator.
[] Donotkink ordamage theflexible m etal tubing w hen moving
therange.
Rigid pipe connection:
The rigid pipe connection requires a combination
of pipe fittings
to obtain an in-line connection to the range. The rigid pipe must
be level with the range connection. All strains must be removed
from the supply and fuel lines so range will be level and in line.
[]
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve. This valve should be located in the same room but
external to the range. It should be in a location that allows
ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the
range.
A
\
B .....................
C
A. Shutoffvalvein "open"position
B.Gassupplyline
C. Torange
Gas Pressure
Regulator
The gas pressure regulator supplied with this range must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natural Gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP Gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet
pressure.
Burner input Requirements
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level.
Gas Supply
Pressure
Testing
Line pressure testing
above r/2psi gauge (14" WCP)
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
rA psi (3.5 kPa).
Line pressure testing
at r/2psi gauge (14" WCP) or lower
The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than r/2psi (3.5 kPa).