GASCONVERSIONS
2. 3.
Explosion Hazard
Use a new CSA International
approved
gas supply line.
Install a shut-off valve.
Securely
tighten
all gas connections.
If connected
to LP, have a qualified
person make sure
gas pressure
does not exceed i4" (36 cm) water
column.
Examples
of a qualified
person
include:
licensed
heating personnel,
authorized
gas company
personnel,
and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
NOTE: Gas conversions (from natural gas to LP gas or from LP
gas to natural gas) must be done by a qualified person.
Unplug or disconnect power.
Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
4.
A.Gas pressureregulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
Remove the cap from the gaspressure regulator using a flat-
blade screwdriver.
Tip Over Hazard
A child or adult can tip the range and be killed,
Connect
anti-tip bracket
to rear range foot,
Reconnect
the anti-tip
bracket,
if the range is moved.
Failure to follow
these instructions can result in death
or serious burns to children
and adults.
To Convert
Gas Pressure
Regulator
1.
12
Ensure that the manual shutoff valve is in the closed position.
A
B ......................
C
_
-
_-_
A. Shutoffvalvein "open"position
B. Gassupplyline
C. Torange
5, Turn the cap over so that LP is visible.
A. Cap
6, Reinstall the cap.
To Convert
Surface
Burners
1, Remove burner grate, burner caps, and burners.
A. Bumer cap
B. Burner