Installation
Instructions
Do This First
(for existing sleeve)
Note that the air conditioner
dimensions
are: 24" wide,
14Y_"high, and 22"
deep (without front). Install Air
Conditioner
according to these installation
instructions
to achieve the best performance.
Save these installation
instructions
for future reference.
Items in Kit
You may not need att parts in the kit. Discard unused
parts.
Tapered Spacer Blocks
Centering/Support
Blocks
Plastic Divider
Stuffer Seat
Seal
Seal
Seal
Seal
Seal
Trim Frame (side legs)
Trim Frame (top & bottom legs)
Ground Wire (green)
Nut for grounding screw
Grounding
Screw
Grille (plastic)
Grille Aluminum
Nuts (plastic)
Screw w/washer
How to Install
17" Long
4Y,"x 3Y,"x I'A ''
1/8" x 4Y_"x 14_A ''
1 "x lY_"x 84"
11/_"x lY_"x 25"
lY_"x lY_"x 14"
1½"x 3/8"x
25"
11A"x 3/8"x
14"
1" x 3/4"x
14"
1. Identify the wall-sleeve
brand for your installation,
from the chart below.
Brand
White-Westinghouse
Frigidaire
Carrier (52F Series)
General Electric/
Hotpoint
Whirlpool
Qty.
2
2
1
1
2
2
2
2
1
2
2
1
1
1
1
1
4
4
Wall Sleeve Dimensions
(inches)
Width
Height
Depth
}25Y_
15_A
17'/_
16,
or 22
26
15%
25%
16'/.
16:A
17,A
or 23
16Y4
or 19_/.
18%
15
18%
163/,
Fedders/Emerson
27
163/4
Sears/Kenmore
25%
167A
Emerson/Fedders
263A
15%
Carrier (51S Series)
253A
16½
Friedrich
27
16%
NOTE: All wall sleeves used to mount the new Air
Conditioner
must be in sound structural condition and
have a rear grille that securely attaches to sleeve, or
rear flange that serves as a stop for the Air Conditioner.
CAUTION: When installation
is complete, replacement
unit MUST have a rearward
slope as shown.
Wail
Sleeve
REAR
i
2. Remove old Air Conditioner from wall sleeve and
prepare wall sleeve as follows:
-- Clean interior (do not disturb seals).
-- Wall sleeve must be securely fastened in wall before
installing Air Conditioner.
Drive more nails or screws
through sleeve, into wall, if needed.
-- Repair paint if needed.
3. If not existing, drill a 3/16"clearance
hole for ground-
ing screw through left side of wall sleeve, in a clear area
about 3 inches maximum (to suit) back from front edge
of sleeve as shown below. Next attach ground wire inside
sleeve, using grounding screw, nut washer pull loose
end of ground wire out front of sleeve, and temporarily
bend it down and around lower edge of sleeve.
Waseev
j 3 1
sleeve grounding
Max I_-
Hole
4. Prepare the wall sleeve for installation
of the new unit
per the following Brand instructions.
#1 Emerson
15" Deep
#2 Fedders
19_" Deep
#3 Fedders or Friedrich
16_" Deep
#4 General Etectric/Hotpoint
16_" Deep
#5 Sears or Carrier (51S Series)
18%" Deep
#6 Whirlpool
17'A" Deep
#7 Whirlpool
23" Deep
#8 White-Westinghouse/Frigidaire/
16"+ 17'/_"Deep
Carrier (52F Series)
#9 White-Westinghouse/Frigidaire
22" Deep
5. Install new unit into wall sleeve.
6. To attach ground wire to the new unit, remove the
screw from the left side front.
7. Assemble
and install the
Trim Frame (see instruction).
P/N 220218A029