_
WARNING
1"heProduct MUST NOT
be plugged in at this
stage.
6.
If required, trim the Single Connector to the size which matches the waste
lee or air break to Ix, used. There are ribs provided to guide cutting.
1
When using tile Single Connector, the hose should be pushed in firmly,
5 clicks.
Remember to slip the Wire Clip over the Drain Hose belore connecting to
the Single Connector.
The supplied Wire Clip should be installed between the two positioning
ribs on the Single Connector.
Attach Single Connector to waste tee. (See Step 2.5) Ensure snugfit
using the supplied hose clamp,
e
¥
Ensure there is a power outlet in reach of tile supplied flex. If there is noi
suilable outlet available then have one installed by a qualified electrician.
DO NOT modify the power plug supplied with the DishDrawer or use an
extension cord, adaptor plug or m_tiple
outlet box.
Neutral
Live
o
Alternatively, the
Oisbbrawer may be
permanently connected
to flexible conduit.
Remove the flex and
cable clamp. Fit suitable
cable clamp for the
conduit and terminate
the wiring as shown.
Use the solderless lug
and washer supplied
with the product paris to
t_minate
the ground
wire.
Page DS 11