Stacking PowerConnect 10G Switches: M8024-k, 8024, 8024F
console(config)#switch 4 renumber 3
The switch will be reset to perform unit renumbering
and the configuration of switch interfaces will be cleared.
Are you sure you want to renumber? (y/n)y
Allow a few minutes for the switch to renumber, then enter the following.
console(config)#do show switch
Management Standby
SW
Status
Status
--- ---------- --------- ------------- ------------- ------------- -------
1
Mgmt Sw
2
Stack Mbr
Oper Stby PC8024F
3
Stack Mbr
4
Unassigned
The switch that was Unit #4 is now Unit #3. Unit #4 is no longer present. To remove it from the list,
perform the no member command for a second time as shown in Stack Configuration Mode.
console(config)#stack
console(config-stack)#no member 4
console(config-stack)#do show switch
Management Standby
SW
Status
Status
--- ---------- --------- ------------- ------------- ------------- -------
1
Mgmt Sw
2
Stack Mbr
Oper Stby PC8024F
3
Stack Mbr
Note: Consult the User Guide for additional stacking information.
Web Interface Method
Since any SFP+ interface on these switches can be used for stacking, be sure to verify exactly which
ports are being used so they are un-cabled and re-routed last.
1. Select System > Stack Management > Stack Port Summary.
Preconfig
Plugged-in
Model ID
Model ID
PC8024
PC8024
PC8024F
PC8024F
PC8024F
PC8024F
Preconfig
Plugged-in
Model ID
Model ID
PC8024
PC8024
PC8024F
PC8024F
PC8024F
Switch
Code
Status
Version
OK
4.2.0.1
OK
4.2.0.1
OK
4.2.0.1
Not Present
0.0.0.0
Switch
Code
Status
Version
OK
4.2.0.1
OK
4.2.0.1
OK
4.2.0.1
52