Installation
Instructions
[_
CONNECTING
INLET
HOSES (on some
models)
To produce steam, the dryer must connect to the cold
water supply. Since the washer must also connect to the
cold water, a ",7" connector is inserted to allow both inlet
hoses to make that connection at the same time.
NOTE: Use the new inlet hoses provided; never use old
hoses.
1. Turn the cold water faucet off. Remove the washer inlet
hose from the washer fill valve connector (cold).
2. Ensure the rubber fiat washer is in place and screw the
female coupling of the short hose onto the washer fill
valve connector. Tighten by hand until firmly seated.
3. Attach the female end of the '"7" connector to the mule
coupling of the short hose. Ensurethe rubber fiat washer
is in place. Tighten by hand until firmly seated.
4. Insert the filter screen in the coupling of the washer's
inlet hose. If a rubber fiat washer is already in place
remove it before installing the filter screen. Attach this
coupling to one male end of the '"7" connector. Tighten
by hand until firmly seated.
5. Ensure the rubber fiat washer is in place and attach the
dryer's long inlet hose to the other male end of the '"7"
connector. Tighten by hand until firmly seated.
6. Ensure the rubber fiat washer is in place and attach
the other end of the dryer's long inlet hose to the fill
valve connector at the bottom of the dryer back panel.
Tighten by hand until firmly seated.
[]
CONNECTING
INLET HOSES {cont.}
7. Using pliers, tighten all the couplings with an additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the couplings may
result.
8. Turn the water faucet on.
9. Check for leaks around the '"7" connector, faucet and
hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUSTbe installed within 42 in.
(107 cm) of your washer's water inlet. The faucets MUST
be 3/4 in. (1.9 cm) garden hose-type so inlet hoses can
be connected. Water pressure MUSTbe between 10 and
120 pounds per square inch. Your water department can
advise you of your water pressure.
NOTE:A water softener is recommended to reduce buildup
of scale inside the steam generator if the home water
supply is very hard.
[]
SERVICING
kWARNING
- LABEL ALL WIRES
PRIOR TO DISCONNECTING
WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER
SERVICI NG/I NSTALLATI O N.
For servicing phone numbers for replacement parts, and
other information, refer to Owner's Manual or visit our
Web site.
REGISTERYOUR NEW APPLIANCE TO RECEIVEANY
IMPORTANT PRODUCT NOTIFICATIONS.
Pleose go to www.GEAppliances.com
or moil in your
Product Registrotion Cord.
For questions on installation, call: 800.626.2000 (US)or
800-561-3344 (Canada).
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ghdp490ef1wwGldp280ed2wsGhdn520ed2wsGhdp490ef0wwGtdp220ef0wwGlds560ed2ww ... Show all

Table of Contents