Installation
instructions
Minimum
Clearance
Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening (]re: 0 in. clea]ra]nceboth sides and i in. rear.
Considera]tion must be given to provide a]dequa]teclea]ra]ncefor insta]lla]tiona]nd service.
[_]PREPARING FOR INSTALLATION
OF
NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer
exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
, Remove and discard existing
plastic
or metal
foil transition
duct and replace with UL listed
transition duct.
WALL
INTERNAL
DUCT
CHECK THAT EXHAUST
OPENING
../HOOD DAMPER OPENS
AND CLOSES
FREE L Y.
TILTTHE DRYERSIDEWAYS
AND REMOVETHE FOAM
SHIPPING PADS BY
PULLING ATTHE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECESAROUND
THE LEGS,
F21ELECTRICAL CONNECTION
INFORMATION
t WARNING - TOREDUCE
THE
RISK OF FIRE, ELECTRICAL SHOCK AND
PERSONAL INJURY:
,, DO NOT USE AN EXTENSION
CORD OR AN
ADAPTER
PLUG WITH THIS APPLIANCE.
Dryer must be electrica]lly grounded in a]ccorda]ncewith
Ioca]l codes a]nd ordina]nces, or in the a]bsence of Ioca]l
codes, in a]ccorda]nce with the NATIONAL ELECTRICAL
CODE,ANSI/NFPANO.70.
ELECTRICAL REQUIREMENTS
This dryer must be connected to a]nindividua]l bra]nchcircuit,
protected by the required time-dela]yfuses or circuit brea]kers.
A four or three-wire, single pha]se,120/240V or 120/208V,
60Hz,:30a]mpcircuit is required. If the electric supply does not
meet the a]bovespecifica]tions, t hen ca]lla]licensed electricia]n.
GROUNDING
INSTRUCTIONS
Thisdryer must be connected to a]grounded metal, perma]nent
wiring system, or a]nequipment-grounding conductor must
be run with the circuit conductors a]nd connected to the
equipment-grounding termina]l on the a]pplia]nce.
CONNECTING
DRYER USING 4-WIRE
CONNECTION
(MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: Since January
l, 1996, the National
Electric
code requires that the new constructions
utilize a
4-wire connection to an electric dryer.
WARNING:
Only a 4-conductor
cord shall
be used when the appliance is installed in a location
where grounding
through
the neutral
conductor
is
prohibited. Grounding through the neutral is prohibited
for the new branch-circuit
installations,
mobile homes,
recreational
vehicles, and areas where
local codes
prohibit grounding through the neutral conduction.
Remove
ground
strop
Fuse
Screw
Hot
Relocate
and discard,
Keep
Wire
green
green ground
screw
ground
_.Xk
_
screw
-1
3/4" UL
Relief
Recognized
Bracket
Strain Relief
4 #10 AWG minimum copper conductors or 120/240V 30A power supply
cord kit marked for use with dryers and provided with closed loop or
spade terminals with upturned ends (not supplied).
1.Turn off the circuit brea]ker(s)(30 a]mp)or remove the
dryer's circuit fuse a]t the electrica]l box,
2. Be sure the dryer cord is unplugged from the wa]ll
recepta]cle,
3. Removethe power cord cover Ioca]teda]tthe lower ba]ck.
4. Remove a]nd disca]rd ground stra]p. Keep the green
ground screw for step 7.
5. Insta]ll 3/4 in. UL recognized stra]in relief to power cord
entry hole. Bring power cord through stra]in relief.
6. Connect power cord a]sfollows:
A. Connect the 2 hot lines to the outer screws of
the termina]l block (ma]rked L1 a]nd L2).
B. Connect the neutra]l (white) line to the center of
the termina]l block (ma]rked N).
7. Atta]ch ground wire of power cord with the green
ground screw (hole a]bove stra]in relief bra]cket).Tighten
a]lltermina]l block screws (3)securely.
8. Properly secure power cord to stra]in relief.
9. Reinsta]llthe cover.
i, W ARNING:
NEVER
LEAVE THE
!
COVER OFF OF THE TERMINAL
BLOCK.