Installation
Instructions
iZ-i_]MOBILE OR MANUFACTURED
HOME
INSTALLATION
. Installation MUST conform to the MANUFACTURED
HOME CONSTRUCTION& SAFETYSTANDARD,
TITLE 24, PART32-80 or, when such standard is not
applicable, with AMERICAN NATIONAL STANDARD FOR
MOBILE HOME, ANSl/NFPA NO. 501B.
. The appliance MUSTbe vented to the outdoors with
the termination securely fastened to the mobile home
structure.
. The vent MUST NOT be terminated beneath a mobile or
manufactured home.
. The vent duct material MUST BE METAL.
• KIT14-D346-33MUSTbe usedto attach the appliance
securelyto the structure.
• Thevent MUSTNOTbe connectedto any other duct, vent, or
chimney.
. Do not use sheet metal screws or other fastening
devices which extend into the interior of the exhaust
vent.
• Providean opening with a free area of at least 25 sq. in.or
introduction of outside air into the dryer room.
ALCOVE OR CLOSET INSTALLATION
. If your appliance is approved for installation in an
alcove or closet, it will be stated on a label on the
appliance back.
• The dryer MUSTbe vented to the outdoors.Seethe EXHAUST
INFORMATION section.
. Do not install this appliance with less than the minimum
clearances shown above.
• The closetshould be vented to the outdoors to prevent gas
pocketingin case of a gas leak in the supply line.
• No other fuel-burning applianceshall be installed in the same
closetwith the appliance.
CONSIDERATION
MUST BE GIVEN TO PROVIDE
ADEQUATE
CLEARANCES
FOR INSTALLATION
AND SERVICE.
A CAUTION: DO NOT INSTALL
THIS
APPLIANCEIN A CLOSETWITH A SOLID DOOR.
DOOR VENTILATION
OPENING {27"
MODELS)
A minimum of 120 square inches of opening, equally
divided at top and bottom, is required. Air openings are
required to be unobstructed when a door is installed.
A Iouvered door with equivalent air openings for the
full length of the door is acceptable.
27" Model
Sq. In.
Ml: o%
.,n.
When louvers or registers are placed in door openings, the
free air openings of the louvers or registers must equal 120
square inches.
DOOR VENTILATION
OPENING {24"
MODELS)
A minimum of 72 square inches of opening is required. Air
openings are required to be unobstructed when a door is
installed. A Iouvered door with equivalent air openings for
the full length of the door is acceptable.
24" Model
/o /
[ii1 J'
IJ I'ii't ; 4 Sq. In.
I'1
H T
When louvers or registers are placed in door openings, the
free air openings of the louvers or registers must equal 72
square inches.
IT47BATHROOM OR BEDROOM INSTALLATION
. The appliance MUST be vented to the outdoors. See
EXHAUSTINFORMATION section 6 & 7.
. The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70 and NATIONAL FUEL GASCODE,
ANSIZ223..
11