REQUIREMENTS
LOCATION
This appliance must be installed on firm flooring to
minimize vibration during spin cycle. Concrete flooring is
best, but wood base is sumcient, provided floor support
meets FHA standards. This appliance should not be
installed on rugs or exposed to weather.
PLUMBING
WATERPRESSURE - Must be 20 psi minimum to 120 psi
maximum.
WATERTEMPERATURE - Household water heater should be
set to deliver water at 120° to 150°F (50° to 66°C)IN THE
WASHERwhen hot wash is selected.
SHUTOFFVALVES - Both hot and cold shutoff valves
(faucets) should be supplied.
DRAIN- Water may be drained into standpipe or set tub.
Discharge height MUSTNOT BE LESS THAN 30 INCHES,
and no more than 6 feet above the base of the washer.
Standpipe must be 1-1/2 inches minimum inside diameter
and must be open to atmosphere.
nstructions
ELECTRICAL
REQUIREM
ENTS
CAUTION:
Before plugging
in washer, read the follow-
ing electrical
requirements.
CAUTION:
For personal safety, do not use an
extension
cord or adapter
plug with this appliance.
Do
not, under any circumstances,
cut or remove the third
grounding
prong from the power cord. Follow national
electrical
codes and ordinances.
This appliance
must be
supplied with the voltage and frequency
indicated
on the
rating plate (located at the top of the dryer front panel),
and connected
to an individual,
properly grounded
branch
circuit, protected
by a 15- or 20-amp circuit breaker or
time-delay
fuse. If the electric supply provided does not
meet the above requirements,
call a licensed electrician.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Verify Your Gas Installation (see section 2).
Prepare the Area and Exhaust for Installation of
appliance (see section 1).
Check and Insure the Existing External Exhaust
is Clean (see section 1) and Meets Attached
Installation Specifications (see section 6).
Remove the Foam Shipping Pads (see section 1).
Move the appliance to the Desired Location.
Level your appliance (see section 8).
Connect the Gas Supply (see section 3) and check
for leaks (see section 4).
Connect the External Exhaust (see section 7).
Connect to plumbing facilities (see section ilk
Step 10 Connect the Power Supply (see section 5).
Step 11 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 12 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation see section 13.
For Bathroom or Bedroom Installation see section 14.
For Mobile or Manufactured Home see section 12.
ADJUSTING
FOR ELEVATION
• Gas clothes dryers input ratings are based on sea level
operation and need not be adjusted for operation at or
below 2000 ft. elevation.
For operation at elevations above 2000 ft., input ratings
should be reduced at a rate of 4 percent for each 1000
ft. above sea level.
• Installation must conform to local codes and ordinances or,
in their absence, the NATIONAL FUELGASCODE,ANSIZ223.