Circulating Air Filters - Goodman GMPN100 Installation & Operating Instructions Manual

Condensing gas furnace gmpn series
Table of Contents

Advertisement

INTEGRATED
FAN / IGNITION
CONTROL
This furnace
is equipped
with a combination
ignition module and fan control. An electronic
device
ignites the burners upon a call for heat. It also controls the venter blower and the various speed
selections
of the circulating
air blower. This control is located in the circulating
air blower
compartment.
Upon a demand
for heat the venter is energized.
After a short purge, the electronic
ignition device is energized.
The burners are ignited after a short delay and the burner flame is
proven. The circulating
air blower is energized
approximately
thirty (30) seconds
after the burners
are ignited. The circulating
air blower off time is field selectable.
THIS CONTROL
IS NOT FIELD
SERVICEABLE.
I
CIRCULATING
AIR FILTERS
1
One of the most common
causes of problems
in a forced air heating system is blocked or dirty
filters. Circulating
air filters must be inspected
monthly for dirt accumulation
and replaced
if
necessary.
Failure to maintain
clean filters can cause premature
heat exchanger
failure. A new
home may require more frequent
replacement
until all construction
dust and dirt is removed.
Circulating
air filters are to be installed
external to the furnace
cabinet.
Before performing
any service on this furnace,
including
checking
or replacing
circulating
air filters
- disconnect
main power.
DO NOT operate the furnace
for extended
periods of time without filters in place. Dust and dirt in
the air will restrict the air movement
over the secondary
coil causing
nuisance
cycling of safety
controls which may result in a "no heat condition."
INPUT BTUH
40,000
60,000
80,000
100,000
120,000
MINIMUM
FILTER SIZES
FILTER SIZE
320 / 160 IN. z
480 / 240 IN. z
640 / 320 IN. z
727 / 363 IN. z
960 / 480 IN. z
TYPE
DISPOS./PERMAN.
DISPOS./PERMAN.
DISPOS./PERMAN.
DISPOS./PERMAN.
DISPOS./PERMAN.
I
TEMPERATURE
RISE
1
The temperature
difference
between
the outlet air and the inlet air of the furnace
is known as the
temperature
rise. This furnace
is designed
to operate within the temperature
rise displayed
on the
furnace
series and rating plate. To ensure satisfactory
performance,
the temperature
rise of the
furnace
must be measured
and adjusted
if necessary.
Use the following
procedure
to measure
and adjust the temperature
rise;
Prior to starting the furnace visually
inspect all joints and seams in the supply and return air
ducts for leaks. Repair them if necessary.
Adjust the room thermostat
to obtain constant
operation.
Allow the furnace
to operate for at least fifteen (15) minutes.
With an accurate
thermometer
measure
the temperature
at the return air grille. If a
combination
indoor / outdoor system is used, the temperature
must be measured
downstream
of the connection.
IO-151
17