Ifcabinet has a drawer, a4"(10.2 cm) d epth clearance from the
countertop tothe topofthedrawer (orother o bstruction) inbase
cabinet isrequired. The drawer depth may need tobeshortened
toavoid interfering withtheregulator.
Ifinstalling arange h oodormicrowave hood combination
above
thecooktop, follow therange h ood ormicrowave hood
combination
installation instructions
fordimensional
clearances
above t hecooktop s urface.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord,
Failure to follow these instructions can result in death,
fire, or electrical shock.
IMPORTANT: The cooktop must be electrically grounded in
accordance
with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1,
This cooktop is equipped with an electronic ignition system that
will not operate if plugged into an outlet that is not properly
polarized.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended.
It is recommended
that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop.
See
"Wiring Diagrams" section.
.,upp I/Reo s n ,menh
Explosion
Hazard
Use a new CSA International
approved
gas supply
line.
install a shut-off valve.
Securely tighten
all gas connections.
if connected
to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples
of a qualified
person include:
licensed
heating personnel,
authorized
gas company
personnel,
and
authorized
service
personnel,
Failure to do so can result in death, explosion,
or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances.
In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT:
Leak testing of the cooktop must be conducted
according to the manufacturer's
instructions.
Type of Gas
Natural Gas:
This cooktop is design-certified
by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
This cooktop is factory set for use with Natural gas. To
convert to LP gas, see the Gas Conversion
instructions
provided in the literature package. The model/serial
rating
plate located on the underside of the cooktop base has
information
on the types of gas that can be used. If the types
of gas listed do not include the type of gas available, check
with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See the Gas
Conversion instructions
provided in the literature package.
Gas Supply Line
Provide a gas supply line of 3/4"(1.9 cm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufficient gas supply. Pipe-joint compounds
that
resist the action of LP gas must be used. Do not use
TEFLON _t tape. With LP gas, piping or tubing size can be r/2"
minimum. Usually, LP gas suppliers determine the size and
materials used in the system.
1-®TEFLON is a registered
trademark
of E.I. Du Pont De Nemours and Company.