Amana AEP222VAW0 Installation Instructions Manual page 7

20" (50.8 cm) freestanding electric range with standard clean oven
Hide thumbs Also See for AEP222VAW0:
Table of Contents

Advertisement

Available languages

Available languages

Power Supply Cord
Direct Wire
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1=
2.
3.
Disconnect
power
Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover.
o
A. Hold-down
screws
B. Terminal block cover
Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
B
A. UL listed strain relief - large opening
B. Small opening
Feed the power supply cord through the strain relief on
the cord/conduit
plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws and rotate/
conduit plate 180°.
A
A. Large opening
B. Small opening
Position cord/conduit
plate as shown in the following
illustration.
A. Small opening
B. Large opening

Advertisement