Amana AEP222VAW0 Installation Instructions Manual page 10

20" (50.8 cm) freestanding electric range with standard clean oven
Hide thumbs Also See for AEP222VAW0:
Table of Contents

Advertisement

Available languages

Available languages

3.
Direct Wire Installation:
Copper or Aluminum
Wire
This range may be connected directly to the circuit breaker box
or fused disconnect.
Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
1Jt
Pull the conduit through the strain relief on cord/conduit
plate
on bottom of range. Allow enough slack to easily attach
wiring to the terminal block.
A
....................................
(7.6 crn)
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
4-wire Connection:
Direct Wire
Use this method for:
New branch-circuit
installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
4=
G
A. Terminal block
B. Ground-link
screw
C. Cord/conduit
plate
D. Line 2 (red) wire
E. Neutral
(white)
wire
F. Line
1 (black)
wire
G. Bare
(green)
ground
wire
Attach terminal lugs to line 1 (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the set screw on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten set screw to torque
as shown in the following Bare Wire Torque Specifications
chart.
A
2.
A
B
C
A. Metal ground strap
B. Discard
C. Ground-rink screw
Use Phillips screwdriver to remove the ground-link
screw
from the back of the range. Save the ground-link
screw and
the end of the ground-link
under the screw.
C
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
5. Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link
screw. The ground wire
must be attached first and must not contact any other
terminal.
10