11.3

MULTIPLE UNIT OPERATION

There are several options for installation of multiple units in close proximity. The following list of
examples will be helpful in determining an appropriate method of connection.
For proper operation, each walk-through metal detector must be set to receive no interference from
adjoining units. This can be determined by observing the bar graph indication of one unit while
switching the remaining unit(s) from Standby to Operate. If the noise flicker increases on the BAR
GRAPH of a unit, then it may be necessary to select another set-up.
11.3.1
CASE I
Description:
• Two (2) units which interfere with each other;
• Both units plugged into same power line (same circuit breaker).
Procedure:
• Set both units to MASTER ;
• Set one unit to CHANNEL A ;
• Set one unit to CHANNEL B.
11.3.2
CASE II:
Description:
• Three (3) or more units that interfere with each other;
• All units plugged into same power (same circuit breaker).
Procedure:
• Set all units to Master
• Set first unit to CHANNEL A
• Set second unit to CHANNEL B
• Set third unit to CHANNEL D ;
Repeat pattern of CHANNELS A,C, and D for any additional units.
11.3.3
CASE III:
Description:
• Three (3) or more units that interfere with each other;
• Units not plugged into the same power line or units with battery back-up option which may be
required to operate in the absence of AC power.
• With the exception of the first and last units, the SH-3 jumper must be removed. This jumper is
located on the Controller Board Assembly. Refer to the drawing for exact location.
© 2009 GARRETT METAL DETECTORS
CS 5000
User Manual
38
PN 1530100 REV H