such as when luggage or supply carts pass by, or when lack of space requires the unit to be placed
very near a conveyor belt of parcel X-ray equipment, the sensor will effectively inhibit alarms.
3. The IR Analysis provides a warning any time a person passes through the archway when the unit
is in the Set-Up or Self-Test Mode.
4. The IR Analysis enables the detector to count the number of individuals passing through it.
6.4
ALARM LEVEL READING
Computerized circuitry of the Garrett CS 5000 permits the unit to report the minimum
sensitivity level required to cause an alarm for the particular metallic target that is being passed
through the archway. This information can then be used to regulate the unit.
Press the ACCESS touchpad until PLEASE WAIT appears on the LCD Display, followed by ALARM
LEVEL and a number. The target in question should then be passed through the unit. Note the Alarm
Reading number that then appears on the LCD. This is the Sensitivity level that will be necessary
for the unit to sound an alarm on this target. Press the + touchpad to reset the indicator after each
measurement. It is recommended that several measurements of each object in question be made at
various archway positions to obtain the optimum sensitivity level setting.
Press ACCESS for next adjustment or OPERATE to return to normal operation.