Garrett CS 5000 User Manual page 17

Hide thumbs Also See for CS 5000:
Table of Contents

Advertisement

Press ACCESS for the next adjustment or OPERATE to return to normal operation.
5.6
RELAY
This feature allows the AC and DC relay circuits to be changed easily to Normally Open (N/O) or
Normally Closed (N/C) to meet installation requirements. Use + and - touchpads to select RELAY
N/C or RELAY N/O (See Section 11.4). Press ACCESS for next adjustment or OPERATE to return
to normal operation.
5.7
ALTER ACCESS CODE #1
This Supervisor Adjustments Code has been preset at the factory at 1234. To change this code:
1. Press the + touchpad.
2. Enter a new four-digit code.
3. The LCD display will prompt REPEAT CODE.
4 . Enter the same four digits of the new code and it will be set and CODE ENTERED OK will be
displayed. (If different digits are entered, the display will indicate INVALID ENTRY, and steps B, C
and D must be repeated.)
Press ACCESS for next adjustment or OPERATE to return to normal operation.
5.8
ALTER ACCESS CODE #2
This Installation Access Code has been preset at the factory at 5678. To change this code:
1. Press the + touchpad.
2. Enter a new four-digit code.
3. The LCD display will prompt REPEAT CODE.
4. Enter the same four digits of the new code and it will be set and CODE ENTERED OK will be
displayed. (If different digits are entered, the display will indicate INVALID ENTRY, and steps B,
C and D must be repeated.)
5. Press OPERATE to exit the Adjustment Mode and enable the detector to be
operated normally. If ACCESS is pressed, this Installation Adjustment cycle will be repeated,
beginning with Receiver Balance.
5.9
RESETTING FACTORY DEFAULT ACCESS CODES
If a code number is ever lost or forgotten, codes may be reset to factory default
settings through the following procedure:
• Open the main cover of the Detection Unit;
• Remove the three (3) screws that hold the Controller Circuit Board cover;
• With power connected and the unit in its Operate Mode press the Access Code Reset button in the
upper center of the circuit board.
• ACCESS CODE #1 will again be 1234 and ACCESS CODE #2 will be 5678.
©2009 GARRETT METAL DETECTORS
CS 5000
User Manual
17
PN 1530100 REV H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

11674xx