GAS CONVERSIONS
IMPORTANT: Gas conversions from Natural gas to LP gas must
be done by a qualified installer.
Explosion
Hazard
Use a new CSA International
approved
gas supply line.
install a shut=off vane.
Securely tighten
all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples
of a qualified person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti=tip bracket to rear range foot.
Reconnect the anti=tip bracket,
if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Remove screws from kick plate.
2.
3.
4=
A. Kick plate
B. Remove these screws.
Push up on kick plate to release plate from shoulder screws.
Gently lay kick plate aside to avoid scratching the stainless
steel.
Locate the gas pressure regulator at the left rear of the range.
5=
A
A. Gas pressure
regulator
Remove the gas pressure regulator cap by using a large flat-
blade screwdriver, turning the regulator cap
counterclockwise.
NOTE: Do not remove the spring beneath the cap.
71
1. Turn the manual shutoff valve to the closed position.
...................
B
A
...................................
0
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug range or disconnect power.
13