EP Setup
EP Setup displays the following selections:
•
•
•
•
•
•
•
•
•
EP Defaults
Restores all EP settings to factory default values. Selections are Restore and Do Not Restore.
Fuser Temperature (Fuser Temp)
Changing this setting can reduce media curl or melting of some letterhead images. Selections are Normal
(default), Lower, and Lowest.
Transfer
The transfer can be adjusted to Low, Medium, or High. The default setting is Medium.
Print Contrast
The print contrast can be adjusted to Low, Medium, or High. The default setting is Medium.
Charge Roll
The charge roll can be adjusted to Low, Medium, or High. The default setting is Medium.
Gap Adjust
Adjusts the minimum gap between sheets during printing. This setting reduces speed (pages per minute), but
can be used to reduce curl of printed media and improve stacking in the output bin.
The range is 0 (default) to 255. Adjusting by one results in 9 mm of increased gap.
EP Defaults
Fuser Temperature (Fuser Temp)
Fuser Page Count
Warm up Time
Transfer
Print Contrast
Charge Roll
Gap Adjust
Automatic Darkness Adjustment (Auto Dark Adj)