Test-Rec Mode; Inner Mode - Sharp MD-R3 Service Manual

Hide thumbs Also See for MD-R3:
Table of Contents

Advertisement

• Whenever the DISPLAY/CHARACTER button is pressed in the continuous playback mode, the indication changes as follows.
* Pit section
Continuous playback (SUBQ address indication + C1 error indication) remains.
* Groove section
Continuous playback (ADIP address indication + C1 error indication) remains.
Continuous playback (ADIP address indication + ADIP error indication) remains.
Continuous playback (ADIP address indication + C1 error indication) remains.
: Adress,
: Error late,

10. TEST-REC mode

Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the TIMER/DELETE/CLEAR button. TEST-REC menu
Step 3
Press once the DISPLAY/
CHARACTER button.
Step 4
Press once the MD PLAY button. During search the search output pin 11 is set to "H", and it is
Step 5
Press once the MD STOP button. TEST-REC menu
• If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD PLAY button is pressed while the TEST-REC menu is displayed, continuous record is started from the current pickup position.
• Whenever the TIMER/DELETE/CLEAR button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
0 3 C 0
• Whenever the DISPLAY/CHARACTER button is pressed in the address setting mode, the digit which is changed with -
as follows.
0 0 5 0
0 0 5 0
• The digit of address which has been specified with -
-01H.
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
• If the JOG button is pressed in TEST-REC mode and continuous record mode, the laser record power changes.
(Servo gain changes also according to the record power.)
: Adress,
: Laser power cord

11. INNER mode

Setting Method
Step No.
Step 1
Testmode STOP state
Step 2
Press the NAME/TOC EDIT button. INNER menu
Step 3
Press once the MD PLAY button. INNER switch position measurement
Step 4
Press once the MD STOP button. INNER menu
: Adress
• Press the MD STOP button while the INNER menu is displayed, to shift to the TEST mode STOP state.
: Jump lines
ADRES setting (indication of address initial value)
(returned on "L" when continuous playback is started.Address +
C1 error indication)
0 7 0 0
0 8 A 0
0 0 5 0
0 0 5 0
0 0 5 0
............
/
(SUBQ address and C1 error are also indicated.)
Remarks
Continuous recording
............
+ and DISPLAY/CHARACTER button in the address setting mode is set to +01H/
Remarks
– 27 –
MD-R3
Display
[ t s m
e
]
[ T E S T _ R E C _ _ ]
[ a 0 0 5 0 _ p w
]
[ a
p w
]
[ T E S T _ R E C _ _ ]
/
+ changes
Display
[ t s m
e
]
[ _ _ I N N E R _ _ ]
[s
c
]
[ _ _ I N N E R _ _ ]

Advertisement

Table of Contents
loading

Table of Contents