Focus Offset/Tracking Offset; Low-Pass Filter; Tracking Gain Relay Circuit; Adjustment Points - Sharp MD-R3 Service Manual

Hide thumbs Also See for MD-R3:
Table of Contents

Advertisement

MD-R3
Reference
CD level
1/2 VCC
Figure 16-1 TRACKING ERROR BALANCE
Apply a black tape
(1.2 to 1.5 wide).
It is allowed use any disc in addition
to test disc.
Do not apply the black tape to the
initialization part (TOC).
Figure 16-2 FOCUS OFFSET/TRACKING OFFSET
Do not plug in or unplug the optical pickup
connection cable while power is on.
Otherwise damage may occur.
For your safety do not attempt to adjust
the half-fixed resistor for laser power
adjustment.
OPTICAL PICKUP PWB
Vertically
symmetrical
waveform
0.5~1.5Vp - p
CNP700A
TP751
1
FG1
2
FG2
3
HF
4
TG1
1
5
FG2
6
1/2Vcc
TRACKING
FOCUS
OFFSET
OFFSET
Figure 16-6 ADJUSTMENT POINTS
– 16 –
Adjust to get uniform and minimized
error waveform.
Figure 16-3 FOCUS OFFSET/TRACKING OFFSET
FG1
27k
TP751, pin 1
TG1
TP751, pin 4
1/2 VCC
Figure 16-4 LOW-PASS FILTER
2.2K
TP751,
pin 4
0.0082
(TG1)
100K
100K
TP751,
pin 6
(1/2Vcc)
100K
100K
TP751,
pin 2
0.0082
(TG2)
2.2K
Figure 16-5 TRACKING GAIN RELAY CIRCUIT
CD SERVO PWB
CNS903
VR754
VR753
6
TP751
TRACKING
GAIN
Waveform
observation
point
820P
CH - 1
820P
VV
Signal
transmitter
VV
820P
CH - 2
VR751
VR752
TRACKING
ERROR BALANCE

Advertisement

Table of Contents
loading