Step No.
Setting Method
Step 11
Press once the ENTER button.
Step 12
Press once the ENTER button.
Step 13
Press once the ENTER button.
Step 14
Press once the ENTER button.
Step 15
Press once the ENTER button.
Step 16
Press once the ENTER button.
Step 17
Press once the ENTER button.
Step 18
Press once the ENTER button.
Step 19
Press once the ENTER button.
Step 20
Press once the ENTER button.
Step 21
Press once the ENTER button.
: Setting volue
• Pressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
d) Sled setting
Setting Method
Step No.
Step 1
Testmode STOP state
Step 2
Press the ENTER button seven times.
Step 3
Press once the MD PLAY button. Focus setting menu
Step 4
Press the ENTER button three times.
Step 5
Press once the MD PLAY button. Slide system loop filter gain constant setting
Step 6
Press once the ENTER button.
Step 7
Press once the ENTER button.
Step 8
Press once the ENTER button.
Step 9
Press once the ENTER button.
Step 10
Press once the ENTER button.
Step 11
Press once the ENTER button.
: Setting volue
• Pressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
1. TEMP • Input temperature correction.
• Correct the TEMP. data according to the PWB ambient temperature, and input it.
• Since the temperature rise causes error of temperature sensing part (RF IC), the following requirements must be observed.
1
Perform the TEST mode without mechanical connection.
2
This operation must be performed quickly after power is supplied.

Data correction table

C)
Ambient temperature (
12.2 ~ 15.8
15.9 ~ 19.6
19.7 ~ 23.2
23.3 ~ 26.8
26.9 ~ 30.7
30.8 ~ 34.3
34.4 ~ 37.9
Tracking kick pulse level setting (for one line jump)
Tracking kick pulse level setting (for 10 line jump)
Tracking drive pulse width setting (for one line jump)
Tracking drive pulse width setting (for 10 line jump)
Tracking slip stop time setting (for one line jump)
Tracking slip stop time setting (for 10 line jump)
Tracking slip stop time setting (move)
TCRS comparison level 1 for high reflection
Comparison level in case of COUT generation (playback)
Comparison level in case of COUT generation (pecord)
Auto-move waiting time setting
EEPROM setting menu
Sled setting menu
Slide system loop filter f characteristic constant 2 setting
Sled output limitter setting
Slide servo output dead zone level setting
Slide kick pulse level setting (forced move)
Slide kick pulse level setting (for 10 lines jump auxiliary use)
Slide kick pulse level setting (move)
Temperature correction
-3
-2
-1
0
+1
+2
+3
– 24 –
Remarks
Remarks
EEPROM record value = Microcomputer measurement value +
Correction
*
EEPROM record value
Value to be measured by the microcomputer at +25 C
* Microcomputer measurement value
Value to be measured by the microcomputer at specific
temperature
* Correction value
Correction value for conversion to measurement value at
+25 C (see the table shown left)
Display
[ T R K L V 0 _ _
]
[ T R K L V t _ _
]
[ T D P W o _ _ _
]
[ T D P W t _ _ _
]
[ S L C T 0 _ _ _
]
[ S L C T t _ _ _
]
[ S L C T m _ _
]
[ T C R S C I P _
]
[ C O T L V p _ _
]
[ C O T L V r _ _
]
[ W A I T m_ _ _
]
Display
[ t s m
e
]
[E E P R O M _ S E T]
[ _ _ F o c u s _ _ _ ]
[ _ _ _ S l e d _ _ _ ]
[ S L G _ _ _ _ _
]
[ S L 2 _ _ _ _ _
]
[ S L D L I M _ _
]
[ S L D L E V _ _
]
[ S L K L V k _ _
]
[ S L K L V t _ _
]
[ S L K L V m _ _
]