Auto Pre-Adjustment Mode; Auto Adjustment Mode; Result Sub-Mode - Sharp MD-R3 Service Manual

Hide thumbs Also See for MD-R3:
Table of Contents

Advertisement

MD-R3
2. AUTO pre-adjustment mode (Low reflection disc only)
Setting Method
Step No.
Step 1
Testmode STOP state
Step 2
Press once the ENTER button.
Step 3
Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic
End of adjustment
Step 4
Grating adjustment,
adjustment value output
Press once the MD STOP button. STEP 2
Step 5
Adjustment value output
Press once the MD STOP button. STEP 2 AUTO pre-adjustment menu
: Adjustment name

3. AUTO adjustment mode

Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the ENTER button two times.
Step 3
Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic
End of adjustment
Step 4
Adjustment value output
Press the MD PLAY button.
Press the MD STOP button.
Step 5
Continuous playback (pit section)
Continuous playback (groove section)
Step 6
Press the DISPLAY button.
Press the MD STOP button.
Step 7
Adjustment value output
Press the MD STOP button.
: Adjustment name,

4. RESULT sub-mode

Setting Method
Step No.
Step 1
Testmode STOP state
Step 2
Press the ENTER button three times.
Step 3
Press once the MD PLAY button. Indication of set value
Step 4
Press once the ENTER button.
Step 5
Press once the ENTER button.
Step 6
Press once the ENTER button.
Step 7
Press once the ENTER button.
Step 8
Press once the ENTER button.
Step 9
Press once the ENTER button.
Step 10
Press once the ENTER button.
Step 11
Press once the ENTER button.
Step 12
Press once the ENTER button.
Step 13
Press once the ENTER button.
Step 14
Press once the ENTER button.
Step 15
Press once the ENTER button.
Step 16
Press once the ENTER button.
Step 17
Press once the ENTER button.
AUTO pre-adjustment menu
pre-adjustment is started.
• During automatic adjustment
HAo RFg SAg SBg PTG PCH GTG GCH RCG
SEG RFG SAG HAO HEO TCO LAO
If adjustment is OK, Step 4.
If adjustment is NG, Step 5.
AUTO adjustment menu
adjustment is started.
• In case of high reflection disc
PEG HAG
•In case of low reflection disc
PEG LAG GCG GEG LAG
If adjustment is OK, Step 4.
If adjustment is NG, Step 7.
STEP 5
STEP 2
Continuous playback (groove section)
STEP 2 AUTO adjustment menu
STEP 2 AUTO adjustment menu
: Measurement value,
RESULT sub-menu
Indication of set value
Indication of set value
Indication of set value
Indication of set value
Indication of set value
Indication of set value
Indication of set value
Indication of set value
Indication of set value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
Indication of measurement value
– 20 –
Remarks
changes as follows.
Remarks
changes as follows.
changes as follows.
: Address
Remarks
Display
[ t s m
e
]
[
A U T O
]
[
: _ _ _ _ _ _ ]
[ _ C O M P L E T E _ ]
[ C a n ' t _ A D J . ]
Display
[ t s m
e
]
[ A U T O _ A J S T _ ]
[
: _ _ _ _ _ _ ]
[ _ C O M P L E T E _ ]
[ s
c
]
[ a
c
]
[ a
a
]
[ C a n ' t _ A D J . ]
Display
[ t s m
e
]
[ _ R S T _ Y O B I _ ]
[ R F G : _ _ _ _ _ ]
[ R C G : _ _ _ _ _ ]
[ R T G : _ _ _ _ _
]
[ G T G : _ _ _ _ _
]
[ P C H : _ _ _ _
]
[ G C H : _ _ _ _
]
[ S A G : _ _ _
]
[ S B G : _ _ _
]
[ S E G : _ _ _
]
[ S F G : _ _ _
]
[ H A O :
_ _ _]
[ H B O :
_ _ _]
[ H E O :
_ _ _]
[ H F O :
_ _ _]
[ L A O :
_ _ _]

Advertisement

Table of Contents
loading

Table of Contents