Common Hardware Problems
Problem
System not
operating.
Heater not
operating
Water not clean.
Abnormal
water usage.
Overheating
Low water
flow from jets.
No water
flow from jets.
Usual Cause
• House circuit breaker tripped or in
OFF position.
• Water level too low.
• Heater mode not selected.
• No power to heater.
• Heater not operating.
• Clogged or blocked floor suction or
skimmer.
• Filter clogged (dirty).
• Poor water chemistry.
• Insufficient filtering time.
• Improper maintenance.
• High content of solids in water.
• Excessive evaporation and/or
splashing.
• High ambient temperature
• Operating in FILTER mode-low speed.
• Clogged or blocked suction or
skimmer.
• Dirty filter.
• Jets in OFF position.
• Slice valves closed.
• Pump not primed.
• Adjustable jets turned off.
• House circuit breaker tripped, no
power to system.
• Faulty pump or motor.
• Pump surges.
• Slice valves closed.
Solution
• Reset circuit breaker on house
breaker panel.
• Add water to reach fill line on Weir
door.
• Refer to temperature/heater functioning.
See Control instructions pgs. 9-15.
• Check house circuit breaker.
• Contact dealer.
• Clean floor suction/skimmer. Remove
blockage.
• Clean or replace.
• See Maintenance section, pg. 16.
• Run filtration mode longer.
• See Maintenance section, pg. 16.
• Use clarifier or drain and refill spa.
• Use spa cover and refill as necessary.
• Contact dealer.
• Select hi-speed jets.
• Clean floor suction/skimmer. Remove
blockage.
• Clean or replace.
• Open jets.
• Open slice valves.
• See Priming section page 10.
• Turn on jets.
• Reset circuit breaker at house panel.
• Contact dealer.
• Low water. Check level on weir door.
• Open slice valves.
28