Hints for test institutes

Parameters possible to be checked by the Test Institutes:
• Energy consumption (corrected with final humidity) during the cupboard dry
cotton cycle with nominal load.
• Energy consumption (corrected with final humidity) during the cupboard dry
cotton cycle with half load.
• Final humidity (during Cupboard dry cotton, Iron dry cotton and Cupboard dry
Easy care)
• Condensation efficiency (corrected with final humidity) during cupboard dry
cotton cycle with nominal and half load (with valve/filter of the water recircu-
lation system in OFF position).
All the cycles have to be checked in accordance with IEC 61121 (Tumble dryers for
household use – Methods for measuring the performance).

Installation

The appliance must be moved in vertical position for transport.

Appliance positioning

• It is recommended that, for your convenience, the machine is positioned close
to your washing machine.
• The tumble dryer must be installed in a clean place, where dirt does not build
up.
• Air must be able to circulate freely all round the appliance. Do not obstruct the
front ventilation grille or the air intake grilles at the back of the machine.
• To keep vibration and noise to a minimum when the dryer is in use, it should be
placed on a firm, level surface.
• Once in its permanent operating position, check that the dryer is absolutely level
with the aid of a spirit level. If it is not, raise or lower the feet until it is.
• The feet must never be removed. Do not restrict the floor clearance through
deeppile carpets, strips of wood or similar. This might cause heat built-up which
would interfere with the operation of the appliance.
Hints for test institutes