Automatic Filtration Cycles; Standard Skimming/Heating Mode; Economy Skimming/Heating Mode - Sundance Spas Maxxus Installation & Owner's Manual

Hot tub
Hide thumbs Also See for Maxxus:
Table of Contents

Advertisement

Audio
Maximum power output (45 watts x 4 channel) . . . . . . . . . . . . . . . . .180 W
Continuous power, 20-20 kHz, 4 ohms, 1% THD . . . . . . . . . . . . . . . .18 x 4
Bass boost/cut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10/100±dB/Hz
Treble boost/cut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10/10+/-dB/kHz
General
Nominal power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14.4 VDC
Allowable power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.8-15.6 VDC
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<10 Amp
Speaker impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8 Ohms

9.0 Automatic Filtration Cycles

Your new spa includes a programmable 24-hour circulation pump which
filters the water continuously while using less energy than a common 100
watt light bulb! The circulation pump draws water through the smaller
TM
MicroClean
filter cartridge and effectively removes small debris in your
spa. Note: the 24-hour circulation pump system also supplies heated water
to the spa when the heater turns on. See page 30 for programming
details.
The control system activates a programmable "standard" or "economy"
skimming/heating cycles to remove larger debris missed by the 24-hour
circulation pump filtration system. These cycles utilize pump#1 and the
larger filter cartridge end to quickly clear "skim" the water of large debris
and minimize their "bath-tub ring" effect. Apart from their skimming
benefit, each mode also effects the operation of your spa's heater. Refer to
sections 9.1 and 9.2 below for additional information.

9.1 Standard Skimming/Heating Mode

Standard skimming/heating mode is typically selected by customers in cold
climates where heatup times are extended due to lower ambient tempera-
tures. In this mode, the water temperature is regulated by the set tempera-
ture, 24-hour circulation pump, and heater which turns on as needed. After
the programmed set temperature is reached, the heater turns off and the
circulation pump continues to operate 24-hours to filter and clean your spa
(unless programmed otherwise).

9.2 Economy Skimming/Heating Mode

Economy skimming/heating mode is typically selected by customers in
warm climates where heatup times are minimized due to higher ambient
temperatures. In this mode, the water temperature is regulated by the set
temperature, 24-hour circulation pump, and heater only while a pro-
grammed skimming/heating cycle is running (unless in summer logic; see
note, page 28). Note: this mode consumes less energy than the standard