Appliance Preparation
A. Top Vent
•
Remove the cover plate by removing the four screws
holding it to the top of the appliance. Discard the cover
plate.
Figure 7.1
Cover Plate
•
Remove the center insulation plug.
Figure 7.2
Center Insulation Plug
•
Cut the metal retaining band and fold the sides out.
Figure 7.3
Retaining Band
CAUTION
Sharp Edges
•
Wear protective gloves and safety
glasses during installation.
Heatilator • Novus DV • 4031-550 Rev G • 11/07
•
Fold the center parts of the retaining band up and use to
remove the vent cap.
Figure 7.4
Remove Vent Cap
•
Discard the vent cap, remove and discard the insulation
basket.
Note: Once the vent cap has been removed it CANNOT
be reattached.
Figure 7.5
Insulation Basket
•
Attach the fi rst vent section. It will snap into place. See
Figure 7.6.
Figure 7.6
Attach the First Vent Section