C. Install the Ceiling Firestop
•
Frame an opening 10 in. by 10 in. whenever the vent
system penetrates a ceiling/fl oor (see Figure 6.4).
•
Frame the area with the same sized lumber as used in
ceiling/fl oor joist.
•
When installing a top vent vertical termination appliance
the hole should be directly above the appliance, unless
the fl ue is offset.
•
The ceiling fi restop may be installed above or below the
ceiling. Refer to Figure 6.5.
•
Secure with three fasteners on each side.
•
Do not pack insulation around the vent. Insulation must
be kept away from the pipe.