3

Maintainance and Service

A. Disposal of Ashes
Frequency: When they reach bottom of grate
By: Homeowner
WARNING! Risk of Fire! Ashes could contain hot em-
bers.
Place ashes in a metal container with a tight-fitting lid.
The closed container should be placed on a
noncombustible floor or on the ground, well away from
all combustible materials, pending final disposal.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
Remove screws,
lift top cover.
Top Cover
Cap
Chimney
TR11/TR11T
TR444/TR442
Round Termination Cap
Figure 3.1
Chimney & Termination Cap Cleaning
Remove 4 screws
and lift top pan off.
Cap
Slip
Section
ST1175
ST475
Square Termination Cap
Heat & Glo • EXCLAIM-36, EXCLAIM-42 • 4013-251 Rev i• 3/12
B. Chimney Inspection/Cleaning
Frequency: At least twice a year during heating season
or as recommended by a certified chimney sweep
By: Certified chimney sweep
WARNING! Risk of Fire! Ignited creosote is extremely
HOT. Prevent creosote buildup.
Refer to Figure 3.1 to remove/reinstall termination caps.
Creosote - Formation and Need for Removal
When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture to
form creosote. The creosote vapors condense in the rela-
tively cool chimney flue of a slow-burning fire. As a result,
creosote residue accumulates on the flue lining. When
ignited this creosote makes an extremely hot fire.
WARNING! Risk of Fire! A chimney fire can permanently
damage your chimney system and nearby structures.
In the event of a chimney fire, Hearth & Home Technolo-
gies Inc. recommends
replacement of the chimney, and
inspection of the adjacent structure to the provisions of
NFPA Level III inspection criteria.
The chimney shall be inspected at least twice a year
during the heating season to determine when a creosote
buildup has occurred.
When creosote has accumulated it shall be removed to
reduce the risk of a chimney fire.
Remove 2 screws from
the front and back and
lift the top off.
SCREW
TCT1175
Terra Cotta
Termination Cap
Available US only
1. REMOVE (8) SCREWS
2. LIFT TOP
TOP
TOP
SCREW
DT SERIES
11