Determine the chimney components needed to complete
your particular installation:
Measure the total vertical height of the fireplace installation
from the base of the fireplace assembly to the approximate
location of the bottom of the termination cap.
Subtract the effective height of the fireplace assembly (see
Figure 8.1) from the total vertical height to determine the
overall height of the chimney installation.
Create a schematic for your application similar to Figure
8.1 showing components required (referring to Table
8.1).
Install a ceiling firestop whenever the chimney penetrates
a floor/ceiling.
NOTICE: A maximum of one offset and return may be
used.
CAUTION! Risk of Fire and/or Asphyxiation! DO NOT
connect this fireplace to a chimney flue servicing another
appliance. Do NOT connect to any air distribution duct
or system. These actions could cause overheating/fire
in the chimney flue, or release of exhaust fumes into the
living areas.
24
Heat & Glo • RUTHERFORD-50 • 4059-333 Rev L• 5/11
Termination
Cap
Storm
Collar
Chase Top
Flashing
74 1/8 in.
(1883 mm)
Effective
Height
Figure 8.1
Figure 8.2
(4) Roof
Radiation
Shields
Chimney Section
Attic Insulation
Shield & Collar
Square Frame
Firestop
Chimney Section
Square Frame
Firestop
Chimney Section