Menu Setting - Citizen CL-S700DT User Manual

Direct thermal barcode & label printer
Table of Contents

Advertisement

2
Printer Operation
Mode Settings
[Datamax® Emulation]
Menu Setting Table
Page Setup Menu - allows you to change settings related to the media or print quality.
System Setup Menu - allows you to change settings for the printer hardware and basic control systems.
After Print Menu - changes how the printer reacts after the label has been printed.
Interfaces - changes interface parameters such as baud rate.
Machine Information, Test Mode - allows you to check and/or print test pages and information about the
printer.
Global Config menu - allows you to switch between 3 complete 'config sets' contained within the printer.

Menu Setting

Press the MENU key in print possible status to enter MENU Setup Mode. Use the keys on the operation panel
according to the LCD display to setup the printer. The contents that can be setup on the printer are shown
below. And the items that are actually displayed on the LCD are shown in [ ].
 Datamax® Emulation
Top Menu
Page Setup
System Setup
Sub Menu
Default
Print Speed
7 IPS
Print Darkness
12
Darkness Adjust
00
[Darkness Adj]
Continuous Media
4.00 inch
Length
101.6 mm
[Cont Media Len]
Vertical Position
0.00 inch
[Vertical Pos]
0.0 mm
Horizontal Shift
0.00 inch
[Horizontal Shif ]
0.0 mm
Vertical Image Shift
0.00 inch
[Vertical Image]
0.0 mm
Media Sensor
See Through
Small Media
Off
Adjustment
[Small Media Adj]
Small Media Length
1.00 inch
[Small Media Len]
25.4 mm
Symbol Set
PM
Sensor Monitor
Sensor Level
1.4 V
Paper End Level
2.80 V
Error Reporting
On Printing
[Error Report]
Cover Open Sensor
Off
[Cover Sensor]
Buzzer Select
Exec/Err
Metric/Inch
Inch
[Metric/Inch Sel]
Menu
Remarks
2 to 7 IPS
Printing speed setting.
00 to 30
Adjusting print darkness.
-10 to 10
Fine adjustment of darkness commands.
0.25 to 32.00 inch
Setting media length of continuous media.
6.4 to 812.8 mm
Lower level = during mm mode.
-1.00 to 1.00 inch
Adjusting printing start position.
-25.4 to 25.4 mm
-1.00 to 1.00 inch
Adjusting horizontal image position.
-25.4 to 25.4 mm
0.00 to 32.00 inch
Adjust the off set value in vertical when
0.0 to 812.8 mm
mapping data on a RAM.
See Through
Selecting media sensor.
Reflect
None
On
Setting for small media.
Off
0.25 to 1.00 inch
Setting media length for small media.
6.4 to 25.4 mm
50 symbols
Setting symbol set.
Displays level of sensor that is currently
selected.
0.0 V to 3.0 V
Selects threshold of the sensor.
0.01 V to 3.00 V
Sets the paper end level.
On Printing
Setting for error report.
Immediate
On
Sets the cover open sensor.
Off
Exec/Err
Setting buzzer sounding conditions.
All
Error
Key
None
Inch
Sets the units.
mm
34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents